(subscribe to this query)
6.9
CVSSv2
CVE-2020-29369
An issue exists in mm/mmap.c in the Linux kernel prior to 5.7.11. There is a race condition between certain expand functions (expand_downwards and expand_upwards) and page-table free operations from an munmap call, aka CID-246c320a8cfe.
Linux Linux Kernel
Netapp Solidfire -
Netapp Hci Management Node -
Netapp Hci Storage Node -
Netapp Hci Compute Node -
4.3
CVSSv2
CVE-2007-2768
OpenSSH, when using OPIE (One-Time Passwords in Everything) for PAM, allows remote malicious users to determine the existence of certain user accounts, which displays a different response if the user account exists and is configured to use one-time passwords (OTP), a similar issu...
Openbsd Openssh
Netapp Hci Management Node -
Netapp Solidfire -
Netapp Steelstore Cloud Integrated Storage -
Netapp Hci Storage Node -
10
CVSSv2
CVE-2020-8584
Element OS versions before 1.8P1 and 12.2 are susceptible to a vulnerability that could allow an unauthenticated remote malicious user to perform arbitrary code execution.
Netapp Hci Management Node -
Netapp Solidfire -
Netapp Hci Storage Node -
Netapp Element Os
Netapp Element Os 1.8
6.8
CVSSv2
CVE-2020-15778
scp in OpenSSH up to and including 8.3p1 allows command injection in the scp.c toremote function, as demonstrated by backtick characters in the destination argument. NOTE: the vendor reportedly has stated that they intentionally omit validation of "anomalous argument transfe...
Openbsd Openssh 8.3
Openbsd Openssh
Netapp A700s Firmware -
Netapp Steelstore Cloud Integrated Storage -
Netapp Active Iq Unified Manager
Netapp Solidfire -
Netapp Hci Management Node -
Netapp Hci Storage Node -
Netapp Hci Compute Node -
Broadcom Fabric Operating System -
9 Github repositories
7.2
CVSSv2
CVE-2020-25221
get_gate_page in mm/gup.c in the Linux kernel 5.7.x and 5.8.x prior to 5.8.7 allows privilege escalation because of incorrect reference counting (caused by gate page mishandling) of the struct page that backs the vsyscall page. The result is a refcount underflow. This can be trig...
Linux Linux Kernel
Netapp Cloud Backup -
Netapp Solidfire \\& Hci Management Node -
Netapp Hci Compute Node -
Netapp Solidfire Baseboard Management Controller -
Netapp Solidfire\\, Enterprise Sds \\& Hci Storage Node -
NA
CVE-2023-38426
An issue exists in the Linux kernel prior to 6.3.4. ksmbd has an out-of-bounds read in smb2_find_context_vals when create_context's name_len is larger than the tag length.
Linux Linux Kernel
Netapp Solidfire \\& Hci Management Node -
Netapp H300s -
Netapp H500s -
Netapp H700s -
Netapp H410s -
Netapp Solidfire \\& Hci Storage Node -
NA
CVE-2023-38428
An issue exists in the Linux kernel prior to 6.3.4. fs/ksmbd/smb2pdu.c in ksmbd does not properly check the UserName value because it does not consider the address of security buffer, leading to an out-of-bounds read.
Linux Linux Kernel
Netapp Solidfire \\& Hci Management Node -
Netapp H300s -
Netapp H500s -
Netapp H700s -
Netapp H410s -
Netapp Solidfire \\& Hci Storage Node -
4.6
CVSSv2
CVE-2020-8739
Use of potentially dangerous function in Intel BIOS platform sample code for some Intel(R) Processors may allow an authenticated user to potentially enable escalation of privilege via local access.
Intel Bios -
Netapp Aff Bios -
Netapp Fas Bios -
Netapp Hci Compute Node Bios -
Netapp Hci Storage Node Bios -
Netapp Solidfire Bios -
4.6
CVSSv2
CVE-2020-8740
Out of bounds write in Intel BIOS platform sample code for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.
Intel Bios -
Netapp Aff Bios -
Netapp Fas Bios -
Netapp Hci Compute Node Bios -
Netapp Hci Storage Node Bios -
Netapp Solidfire Bios -
4.6
CVSSv2
CVE-2020-8764
Improper access control in BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.
Intel Bios -
Netapp Aff Bios -
Netapp Fas Bios -
Netapp Hci Compute Node Bios -
Netapp Hci Storage Node Bios -
Netapp Solidfire Bios -
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
blind SQL injection
firmware
CVE-2006-4304
CVE-2024-32878
CVE-2024-31502
XSS
CVE-2024-3059
CVE-2024-33692
CVE-2024-3400
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
3
4
5
6
NEXT »